行業(yè)標(biāo)準(zhǔn)
JGJ82-2011······1
1 總則······11
2 術(shù)語(yǔ)和符號(hào)······12
2.1 術(shù)語(yǔ)······12
2.2 符號(hào)······13
3 基本規(guī)定······16
3.1 一般規(guī)定······16
3.2 材料與設(shè)計(jì)指標(biāo)······17
4 連接設(shè)計(jì)······20
4.1 摩擦型連接······20
4.2 承壓型連接······21
4.3 連接構(gòu)造······23
5 連接接頭設(shè)計(jì)······25
5.1 螺栓拼接接頭······25
5.2 受拉連接接頭······28
5.3 外伸式端板連接接頭······30
5.4 栓焊混用連接接頭······32
5.5 栓焊并用連接接頭······33
6 施工······36
6.1 儲(chǔ)運(yùn)和保管······36
6.2 連接構(gòu)件的制作······36
6.3 高強(qiáng)度螺拴連接副和摩擦面抗滑移系數(shù)檢驗(yàn)······38
6.4 安裝······40
6.5 緊固質(zhì)量檢驗(yàn)······45
7 施工質(zhì)量驗(yàn)收······47
7.1 一般規(guī)定······47
7.2 檢驗(yàn)批的劃分······48
7.3 驗(yàn)收資料······48
本規(guī)程用詞說(shuō)明······50
引用標(biāo)準(zhǔn)名錄······51
附:條文說(shuō)明······53
1 總則······56
2 術(shù)語(yǔ)和符號(hào)······57
2.1 術(shù)語(yǔ)······57
2.2 符號(hào)······57
3 基本規(guī)定······58
3.1 一般規(guī)定······58
3.2 材料與設(shè)計(jì)指標(biāo)······60
4 連接設(shè)計(jì)······62
4.1 摩擦型連接······62
4.2 承壓型連接······62
4.3 連接構(gòu)造······63
5 連接接頭設(shè)計(jì)······65
5.1 螺栓拼接接頭······65
5.2 受拉連接接頭······65
5.3 外伸式端板連接接頭······67
5.4 栓焊混用連接接頭······68
5.5 栓焊并用連接接頭······68
6 施工······70
6.1 儲(chǔ)運(yùn)和保管······70
6.2 連接構(gòu)件的制作······70
6.3 高強(qiáng)度螺栓連接副和摩擦面抗滑移系數(shù)檢驗(yàn)······71
6.4 安裝······72
6.5 緊固質(zhì)量檢驗(yàn)······74
7 施工質(zhì)量驗(yàn)收······76
7.1 一般規(guī)定······76
7.2 檢驗(yàn)批的劃分······76
下載地址
同類標(biāo)準(zhǔn)
JGJ203-2010:民用建筑太陽(yáng)能光伏系統(tǒng)應(yīng)用技術(shù)規(guī)范
時(shí)間:2023-04-03 19:32:16JGJ134-2010:夏熱冬冷地區(qū)居住建筑節(jié)能設(shè)計(jì)標(biāo)準(zhǔn)
時(shí)間:2023-04-03 19:22:46JGJ475-2019:溫和地區(qū)居住建筑節(jié)能設(shè)計(jì)標(biāo)準(zhǔn)
時(shí)間:2023-04-03 19:32:49JGJ26-2018:嚴(yán)寒和寒冷地區(qū)居住建筑節(jié)能設(shè)計(jì)標(biāo)準(zhǔn)
時(shí)間:2023-04-03 19:29:32JGJ/T229-2010:民用建筑綠色設(shè)計(jì)規(guī)范
時(shí)間:2023-04-03 19:26:56JGJ75-2012:夏熱冬暖地區(qū)居住建筑節(jié)能設(shè)計(jì)標(biāo)準(zhǔn)
時(shí)間:2023-04-03 19:27:46